放大器能源利用和热量排放

输入您项目所需的 Extron 放大器的类型和数量。此工具会计算出总输入功率、热负荷和所需的冷却温度。

  • 交流电源输入

    • Ohms
    • Ohms
    • Ohms
    • Ohms

结果

按年计算
输入功率 = 瓦特 千瓦-小时 (Annual Calculation)
散热 = BTU/小时 1000 BTU/小时 (Annual Calculation)
所需的冷却值 =

Extron amplifiers utilize highly efficient Class D designs that draw less power than conventional amplifiers. As ENERGY STAR qualified amplifiers, they also automatically enter a very low power "sleep" mode after 25 minutes in which no signal is present at the input. System designers frequently want to know the energy usage of a rack of amplifiers, as well as how much cooling will be required. Since amplifiers generate significant waste heat, this is a key factor.

This audio tool calculates the total input power draw, thermal dissipation or waste heat, and the required cooling for a collection of amplifiers. Up to four types of Extron amplifiers can be selected from the drop down list. Select the line voltage for the region in which the amplifier will be used, select the type and quantity of amplifiers, select the desired speaker impedance for amplifiers with low impedance outputs, and then press Calculate.

  • Power Draw and Thermal Dissipation figures at 1/8th power output are taken from the individual amplifier product specifications.
  • Cooling Required follows the industry practice of measuring air conditioning cooling capacity in tons. The required capacity is calculated by dividing the BTU/hr heat load by 12,000.
  • Annual Calculation assumes amplifiers are operating for 2,080 hours at 1/8th power, and 6,680 hours in standby mode.

FAQs

It estimates amplifier energy usage and thermal dissipation under typical operating conditions.

Thermal dissipation affects rack ventilation, cooling requirements, and long‑term reliability.

Yes. It provides estimates useful for rack power and cooling planning.

No. Results are based on typical operating conditions, not continuous full power.
数量