近期查看的产品
2LC OM4 MM P
建筑工程规范
选择一个产品编号:
复制文本
已复制!
发生错误。请稍后重试。
2LC OM4 MM P/1
- Provide interconnection for the transmission of high-speed optical digital signals over a duplex multimode fiber optic cable assembly
- Duplex multimode fiber optic cable assembly for transmission of optical digital signals
- Cable construction requirements
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Glass fiber core diameter of 50 µm
- Glass fiber outer diameter of 125 µm
- Shall provide a 900 µm tight buffer coating surrounding each glass fiber
- Shall provide Aramid yarn as the strengthening material surrounding each tight-buffered fiber
- Shall provide a 2 mm diameter, OFNP plenum-rated jacket to meet NEC, CSA, and ICEA safety standards, surrounding each tight-buffered fiber and Aramid yarn strengthening material
- Shall provide duplex zip-cord cable construction for strength and protection of the glass fiber
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Termination requirements
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Pre-polished with an UPC – ultra physical contact end face
- Shall be configured with duplex connectors using AB - BA reverse-pair polarity as described in TIA-568
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Performance requirements
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- TIA 492-AAAD
- IEC 60793-2-10, A1a.3
- ISO/IEC 11801, OM4
- Shall provide attenuation of less than 3.0 dB per kilometer at an 850 nm wavelength
- Shall provide attenuation of less than 1.2 dB per kilometer at a 1300 nm wavelength
- Shall provide an insertion loss of less than 0.5 dB per 300 meters at 850 nm or 1300 nm
- Shall provide minimum effective mode bandwidth of 4700 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 3500 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 550 MHz-km at a 1300 nm wavelength
- Shall be bend-insensitive fiber for a tight bend radius of 0.3 inches (7.5 mm) with minimal cable losses
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- General requirements
- Shall be available in a one (1) meter (3.3 foot) length
- Shall provide an outer dimeter of 0.08" ±0.008" (2.0 mm ±0.2 mm)
- Shall meet regulatory compliance
- ETL/c-ETL OFNP FT6 (plenum rated)
- Shall provide a lifetime limited performance warranty
- Approved cable shall be Extron 2LC OM4 MM P/1 (part number 26-671-01), no alternates or equals
2LC OM4 MM P/1
- Provide interconnection for the transmission of high-speed optical digital signals over a duplex multimode fiber optic cable assembly
- Duplex multimode fiber optic cable assembly for transmission of optical digital signals
- Cable construction requirements
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Glass fiber core diameter of 50 µm
- Glass fiber outer diameter of 125 µm
- Shall provide a 900 µm tight buffer coating surrounding each glass fiber
- Shall provide Aramid yarn as the strengthening material surrounding each tight-buffered fiber
- Shall provide a 2 mm diameter, OFNP plenum-rated jacket to meet NEC, CSA, and ICEA safety standards, surrounding each tight-buffered fiber and Aramid yarn strengthening material
- Shall provide duplex zip-cord cable construction for strength and protection of the glass fiber
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Termination requirements
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Pre-polished with an UPC – ultra physical contact end face
- Shall be configured with duplex connectors using AB - BA reverse-pair polarity as described in TIA-568
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Performance requirements
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- TIA 492-AAAD
- IEC 60793-2-10, A1a.3
- ISO/IEC 11801, OM4
- Shall provide attenuation of less than 3.0 dB per kilometer at an 850 nm wavelength
- Shall provide attenuation of less than 1.2 dB per kilometer at a 1300 nm wavelength
- Shall provide an insertion loss of less than 0.5 dB per 300 meters at 850 nm or 1300 nm
- Shall provide minimum effective mode bandwidth of 4700 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 3500 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 550 MHz-km at a 1300 nm wavelength
- Shall be bend-insensitive fiber for a tight bend radius of 0.3 inches (7.5 mm) with minimal cable losses
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- General requirements
- Shall be available in a one (1) meter (3.3 foot) length
- Shall provide an outer dimeter of 0.08" ±0.008" (2.0 mm ±0.2 mm)
- Shall meet regulatory compliance
- ETL/c-ETL OFNP FT6 (plenum rated)
- Shall provide a lifetime limited performance warranty
- Approved cable shall be Extron 2LC OM4 MM P/1 (part number 26-671-01), no alternates or equals
2LC OM4 MM P/2
- Provide interconnection for the transmission of high-speed optical digital signals over a duplex multimode fiber optic cable assembly
- Duplex multimode fiber optic cable assembly for transmission of optical digital signals
- Cable construction requirements
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Glass fiber core diameter of 50 µm
- Glass fiber outer diameter of 125 µm
- Shall provide a 900 µm tight buffer coating surrounding each glass fiber
- Shall provide Aramid yarn as the strengthening material surrounding each tight-buffered fiber
- Shall provide a 2 mm diameter, OFNP plenum-rated jacket to meet NEC, CSA, and ICEA safety standards, surrounding each tight-buffered fiber and Aramid yarn strengthening material
- Shall provide duplex zip-cord cable construction for strength and protection of the glass fiber
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Termination requirements
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Pre-polished with an UPC – ultra physical contact end face
- Shall be configured with duplex connectors using AB - BA reverse-pair polarity as described in TIA-568
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Performance requirements
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- TIA 492-AAAD
- IEC 60793-2-10, A1a.3
- ISO/IEC 11801, OM4
- Shall provide attenuation of less than 3.0 dB per kilometer at an 850 nm wavelength
- Shall provide attenuation of less than 1.2 dB per kilometer at a 1300 nm wavelength
- Shall provide an insertion loss of less than 0.5 dB per 300 meters at 850 nm or 1300 nm
- Shall provide minimum effective mode bandwidth of 4700 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 3500 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 550 MHz-km at a 1300 nm wavelength
- Shall be bend-insensitive fiber for a tight bend radius of 0.3 inches (7.5 mm) with minimal cable losses
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- General requirements
- Shall be available in a two (2) meter 6.6 (foot) length
- Shall provide an outer dimeter of 0.08" ±0.008" (2.0 mm ±0.2 mm)
- Shall meet regulatory compliance
- ETL/c-ETL OFNP FT6 (plenum rated)
- Shall provide a lifetime limited performance warranty
- Approved cable shall be Extron 2LC OM4 MM P/2 (part number 26-671-02), no alternates or equals
2LC OM4 MM P/2
- Provide interconnection for the transmission of high-speed optical digital signals over a duplex multimode fiber optic cable assembly
- Duplex multimode fiber optic cable assembly for transmission of optical digital signals
- Cable construction requirements
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Glass fiber core diameter of 50 µm
- Glass fiber outer diameter of 125 µm
- Shall provide a 900 µm tight buffer coating surrounding each glass fiber
- Shall provide Aramid yarn as the strengthening material surrounding each tight-buffered fiber
- Shall provide a 2 mm diameter, OFNP plenum-rated jacket to meet NEC, CSA, and ICEA safety standards, surrounding each tight-buffered fiber and Aramid yarn strengthening material
- Shall provide duplex zip-cord cable construction for strength and protection of the glass fiber
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Termination requirements
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Pre-polished with an UPC – ultra physical contact end face
- Shall be configured with duplex connectors using AB - BA reverse-pair polarity as described in TIA-568
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Performance requirements
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- TIA 492-AAAD
- IEC 60793-2-10, A1a.3
- ISO/IEC 11801, OM4
- Shall provide attenuation of less than 3.0 dB per kilometer at an 850 nm wavelength
- Shall provide attenuation of less than 1.2 dB per kilometer at a 1300 nm wavelength
- Shall provide an insertion loss of less than 0.5 dB per 300 meters at 850 nm or 1300 nm
- Shall provide minimum effective mode bandwidth of 4700 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 3500 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 550 MHz-km at a 1300 nm wavelength
- Shall be bend-insensitive fiber for a tight bend radius of 0.3 inches (7.5 mm) with minimal cable losses
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- General requirements
- Shall be available in a two (2) meter 6.6 (foot) length
- Shall provide an outer dimeter of 0.08" ±0.008" (2.0 mm ±0.2 mm)
- Shall meet regulatory compliance
- ETL/c-ETL OFNP FT6 (plenum rated)
- Shall provide a lifetime limited performance warranty
- Approved cable shall be Extron 2LC OM4 MM P/2 (part number 26-671-02), no alternates or equals
2LC OM4 MM P/3
- Provide interconnection for the transmission of high-speed optical digital signals over a duplex multimode fiber optic cable assembly
- Duplex multimode fiber optic cable assembly for transmission of optical digital signals
- Cable construction requirements
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Glass fiber core diameter of 50 µm
- Glass fiber outer diameter of 125 µm
- Shall provide a 900 µm tight buffer coating surrounding each glass fiber
- Shall provide Aramid yarn as the strengthening material surrounding each tight-buffered fiber
- Shall provide a 2 mm diameter, OFNP plenum-rated jacket to meet NEC, CSA, and ICEA safety standards, surrounding each tight-buffered fiber and Aramid yarn strengthening material
- Shall provide duplex zip-cord cable construction for strength and protection of the glass fiber
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Termination requirements
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Pre-polished with an UPC – ultra physical contact end face
- Shall be configured with duplex connectors using AB - BA reverse-pair polarity as described in TIA-568
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Performance requirements
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- TIA 492-AAAD
- IEC 60793-2-10, A1a.3
- ISO/IEC 11801, OM4
- Shall provide attenuation of less than 3.0 dB per kilometer at an 850 nm wavelength
- Shall provide attenuation of less than 1.2 dB per kilometer at a 1300 nm wavelength
- Shall provide an insertion loss of less than 0.5 dB per 300 meters at 850 nm or 1300 nm
- Shall provide minimum effective mode bandwidth of 4700 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 3500 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 550 MHz-km at a 1300 nm wavelength
- Shall be bend-insensitive fiber for a tight bend radius of 0.3 inches (7.5 mm) with minimal cable losses
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- General requirements
- Shall be available in a three (3) meter (9.8 foot) length
- Shall provide an outer dimeter of 0.08" ±0.008" (2.0 mm ±0.2 mm)
- Shall meet regulatory compliance
- ETL/c-ETL OFNP FT6 (plenum rated)
- Shall provide a lifetime limited performance warranty
- Approved cable shall be Extron 2LC OM4 MM P/3 (part number 26-671-03), no alternates or equals
2LC OM4 MM P/3
- Provide interconnection for the transmission of high-speed optical digital signals over a duplex multimode fiber optic cable assembly
- Duplex multimode fiber optic cable assembly for transmission of optical digital signals
- Cable construction requirements
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Glass fiber core diameter of 50 µm
- Glass fiber outer diameter of 125 µm
- Shall provide a 900 µm tight buffer coating surrounding each glass fiber
- Shall provide Aramid yarn as the strengthening material surrounding each tight-buffered fiber
- Shall provide a 2 mm diameter, OFNP plenum-rated jacket to meet NEC, CSA, and ICEA safety standards, surrounding each tight-buffered fiber and Aramid yarn strengthening material
- Shall provide duplex zip-cord cable construction for strength and protection of the glass fiber
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Termination requirements
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Pre-polished with an UPC – ultra physical contact end face
- Shall be configured with duplex connectors using AB - BA reverse-pair polarity as described in TIA-568
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Performance requirements
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- TIA 492-AAAD
- IEC 60793-2-10, A1a.3
- ISO/IEC 11801, OM4
- Shall provide attenuation of less than 3.0 dB per kilometer at an 850 nm wavelength
- Shall provide attenuation of less than 1.2 dB per kilometer at a 1300 nm wavelength
- Shall provide an insertion loss of less than 0.5 dB per 300 meters at 850 nm or 1300 nm
- Shall provide minimum effective mode bandwidth of 4700 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 3500 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 550 MHz-km at a 1300 nm wavelength
- Shall be bend-insensitive fiber for a tight bend radius of 0.3 inches (7.5 mm) with minimal cable losses
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- General requirements
- Shall be available in a three (3) meter (9.8 foot) length
- Shall provide an outer dimeter of 0.08" ±0.008" (2.0 mm ±0.2 mm)
- Shall meet regulatory compliance
- ETL/c-ETL OFNP FT6 (plenum rated)
- Shall provide a lifetime limited performance warranty
- Approved cable shall be Extron 2LC OM4 MM P/3 (part number 26-671-03), no alternates or equals
2LC OM4 MM P/5
- Provide interconnection for the transmission of high-speed optical digital signals over a duplex multimode fiber optic cable assembly
- Duplex multimode fiber optic cable assembly for transmission of optical digital signals
- Cable construction requirements
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Glass fiber core diameter of 50 µm
- Glass fiber outer diameter of 125 µm
- Shall provide a 900 µm tight buffer coating surrounding each glass fiber
- Shall provide Aramid yarn as the strengthening material surrounding each tight-buffered fiber
- Shall provide a 2 mm diameter, OFNP plenum-rated jacket to meet NEC, CSA, and ICEA safety standards, surrounding each tight-buffered fiber and Aramid yarn strengthening material
- Shall provide duplex zip-cord cable construction for strength and protection of the glass fiber
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Termination requirements
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Pre-polished with an UPC – ultra physical contact end face
- Shall be configured with duplex connectors using AB - BA reverse-pair polarity as described in TIA-568
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Performance requirements
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- TIA 492-AAAD
- IEC 60793-2-10, A1a.3
- ISO/IEC 11801, OM4
- Shall provide attenuation of less than 3.0 dB per kilometer at an 850 nm wavelength
- Shall provide attenuation of less than 1.2 dB per kilometer at a 1300 nm wavelength
- Shall provide an insertion loss of less than 0.5 dB per 300 meters at 850 nm or 1300 nm
- Shall provide minimum effective mode bandwidth of 4700 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 3500 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 550 MHz-km at a 1300 nm wavelength
- Shall be bend-insensitive fiber for a tight bend radius of 0.3 inches (7.5 mm) with minimal cable losses
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- General requirements
- Shall be available in a five (5) meter (16.4 foot) length
- Shall provide an outer dimeter of 0.08" ±0.008" (2.0 mm ±0.2 mm)
- Shall meet regulatory compliance
- ETL/c-ETL OFNP FT6 (plenum rated)
- Shall provide a lifetime limited performance warranty
- Approved cable shall be Extron 2LC OM4 MM P/5 (part number 26-671-05), no alternates or equals
2LC OM4 MM P/5
- Provide interconnection for the transmission of high-speed optical digital signals over a duplex multimode fiber optic cable assembly
- Duplex multimode fiber optic cable assembly for transmission of optical digital signals
- Cable construction requirements
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Glass fiber core diameter of 50 µm
- Glass fiber outer diameter of 125 µm
- Shall provide a 900 µm tight buffer coating surrounding each glass fiber
- Shall provide Aramid yarn as the strengthening material surrounding each tight-buffered fiber
- Shall provide a 2 mm diameter, OFNP plenum-rated jacket to meet NEC, CSA, and ICEA safety standards, surrounding each tight-buffered fiber and Aramid yarn strengthening material
- Shall provide duplex zip-cord cable construction for strength and protection of the glass fiber
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Termination requirements
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Pre-polished with an UPC – ultra physical contact end face
- Shall be configured with duplex connectors using AB - BA reverse-pair polarity as described in TIA-568
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Performance requirements
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- TIA 492-AAAD
- IEC 60793-2-10, A1a.3
- ISO/IEC 11801, OM4
- Shall provide attenuation of less than 3.0 dB per kilometer at an 850 nm wavelength
- Shall provide attenuation of less than 1.2 dB per kilometer at a 1300 nm wavelength
- Shall provide an insertion loss of less than 0.5 dB per 300 meters at 850 nm or 1300 nm
- Shall provide minimum effective mode bandwidth of 4700 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 3500 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 550 MHz-km at a 1300 nm wavelength
- Shall be bend-insensitive fiber for a tight bend radius of 0.3 inches (7.5 mm) with minimal cable losses
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- General requirements
- Shall be available in a five (5) meter (16.4 foot) length
- Shall provide an outer dimeter of 0.08" ±0.008" (2.0 mm ±0.2 mm)
- Shall meet regulatory compliance
- ETL/c-ETL OFNP FT6 (plenum rated)
- Shall provide a lifetime limited performance warranty
- Approved cable shall be Extron 2LC OM4 MM P/5 (part number 26-671-05), no alternates or equals
2LC OM4 MM P/10
- Provide interconnection for the transmission of high-speed optical digital signals over a duplex multimode fiber optic cable assembly
- Duplex multimode fiber optic cable assembly for transmission of optical digital signals
- Cable construction requirements
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Glass fiber core diameter of 50 µm
- Glass fiber outer diameter of 125 µm
- Shall provide a 900 µm tight buffer coating surrounding each glass fiber
- Shall provide Aramid yarn as the strengthening material surrounding each tight-buffered fiber
- Shall provide a 2 mm diameter, OFNP plenum-rated jacket to meet NEC, CSA, and ICEA safety standards, surrounding each tight-buffered fiber and Aramid yarn strengthening material
- Shall provide duplex zip-cord cable construction for strength and protection of the glass fiber
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Termination requirements
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Pre-polished with an UPC – ultra physical contact end face
- Shall be configured with duplex connectors using AB - BA reverse-pair polarity as described in TIA-568
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Performance requirements
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- TIA 492-AAAD
- IEC 60793-2-10, A1a.3
- ISO/IEC 11801, OM4
- Shall provide attenuation of less than 3.0 dB per kilometer at an 850 nm wavelength
- Shall provide attenuation of less than 1.2 dB per kilometer at a 1300 nm wavelength
- Shall provide an insertion loss of less than 0.5 dB per 300 meters at 850 nm or 1300 nm
- Shall provide minimum effective mode bandwidth of 4700 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 3500 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 550 MHz-km at a 1300 nm wavelength
- Shall be bend-insensitive fiber for a tight bend radius of 0.3 inches (7.5 mm) with minimal cable losses
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- General requirements
- Shall be available in a ten (10) meter (32.8 foot) length
- Shall provide an outer dimeter of 0.08" ±0.008" (2.0 mm ±0.2 mm)
- Shall meet regulatory compliance
- ETL/c-ETL OFNP FT6 (plenum rated)
- Shall provide a lifetime limited performance warranty
- Approved cable shall be Extron 2LC OM4 MM P/10 (part number 26-671-10), no alternates or equals
2LC OM4 MM P/10
- Provide interconnection for the transmission of high-speed optical digital signals over a duplex multimode fiber optic cable assembly
- Duplex multimode fiber optic cable assembly for transmission of optical digital signals
- Cable construction requirements
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Glass fiber core diameter of 50 µm
- Glass fiber outer diameter of 125 µm
- Shall provide a 900 µm tight buffer coating surrounding each glass fiber
- Shall provide Aramid yarn as the strengthening material surrounding each tight-buffered fiber
- Shall provide a 2 mm diameter, OFNP plenum-rated jacket to meet NEC, CSA, and ICEA safety standards, surrounding each tight-buffered fiber and Aramid yarn strengthening material
- Shall provide duplex zip-cord cable construction for strength and protection of the glass fiber
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Termination requirements
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Pre-polished with an UPC – ultra physical contact end face
- Shall be configured with duplex connectors using AB - BA reverse-pair polarity as described in TIA-568
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Performance requirements
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- TIA 492-AAAD
- IEC 60793-2-10, A1a.3
- ISO/IEC 11801, OM4
- Shall provide attenuation of less than 3.0 dB per kilometer at an 850 nm wavelength
- Shall provide attenuation of less than 1.2 dB per kilometer at a 1300 nm wavelength
- Shall provide an insertion loss of less than 0.5 dB per 300 meters at 850 nm or 1300 nm
- Shall provide minimum effective mode bandwidth of 4700 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 3500 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 550 MHz-km at a 1300 nm wavelength
- Shall be bend-insensitive fiber for a tight bend radius of 0.3 inches (7.5 mm) with minimal cable losses
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- General requirements
- Shall be available in a ten (10) meter (32.8 foot) length
- Shall provide an outer dimeter of 0.08" ±0.008" (2.0 mm ±0.2 mm)
- Shall meet regulatory compliance
- ETL/c-ETL OFNP FT6 (plenum rated)
- Shall provide a lifetime limited performance warranty
- Approved cable shall be Extron 2LC OM4 MM P/10 (part number 26-671-10), no alternates or equals
2LC OM4 MM P/30
- Provide interconnection for the transmission of high-speed optical digital signals over a duplex multimode fiber optic cable assembly
- Duplex multimode fiber optic cable assembly for transmission of optical digital signals
- Cable construction requirements
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Glass fiber core diameter of 50 µm
- Glass fiber outer diameter of 125 µm
- Shall provide a 900 µm tight buffer coating surrounding each glass fiber
- Shall provide Aramid yarn as the strengthening material surrounding each tight-buffered fiber
- Shall provide a 2 mm diameter, OFNP plenum-rated jacket to meet NEC, CSA, and ICEA safety standards, surrounding each tight-buffered fiber and Aramid yarn strengthening material
- Shall provide duplex zip-cord cable construction for strength and protection of the glass fiber
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Termination requirements
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Pre-polished with an UPC – ultra physical contact end face
- Shall be configured with duplex connectors using AB - BA reverse-pair polarity as described in TIA-568
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Performance requirements
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- TIA 492-AAAD
- IEC 60793-2-10, A1a.3
- ISO/IEC 11801, OM4
- Shall provide attenuation of less than 3.0 dB per kilometer at an 850 nm wavelength
- Shall provide attenuation of less than 1.2 dB per kilometer at a 1300 nm wavelength
- Shall provide an insertion loss of less than 0.5 dB per 300 meters at 850 nm or 1300 nm
- Shall provide minimum effective mode bandwidth of 4700 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 3500 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 550 MHz-km at a 1300 nm wavelength
- Shall be bend-insensitive fiber for a tight bend radius of 0.3 inches (7.5 mm) with minimal cable losses
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- General requirements
- Shall be available in a thirty (30) meter (98.4 foot) length
- Shall provide an outer dimeter of 0.08" ±0.008" (2.0 mm ±0.2 mm)
- Shall meet regulatory compliance
- ETL/c-ETL OFNP FT6 (plenum rated)
- Shall provide a lifetime limited performance warranty
- Approved cable shall be Extron 2LC OM4 MM P/30 (part number 26-671-30), no alternates or equals
2LC OM4 MM P/30
- Provide interconnection for the transmission of high-speed optical digital signals over a duplex multimode fiber optic cable assembly
- Duplex multimode fiber optic cable assembly for transmission of optical digital signals
- Cable construction requirements
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Glass fiber core diameter of 50 µm
- Glass fiber outer diameter of 125 µm
- Shall provide a 900 µm tight buffer coating surrounding each glass fiber
- Shall provide Aramid yarn as the strengthening material surrounding each tight-buffered fiber
- Shall provide a 2 mm diameter, OFNP plenum-rated jacket to meet NEC, CSA, and ICEA safety standards, surrounding each tight-buffered fiber and Aramid yarn strengthening material
- Shall provide duplex zip-cord cable construction for strength and protection of the glass fiber
- Shall provide two (2) 50/125 µm graded-index, bend-insensitive, laser-optimized multimode fibers
- Termination requirements
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Pre-polished with an UPC – ultra physical contact end face
- Shall be configured with duplex connectors using AB - BA reverse-pair polarity as described in TIA-568
- Shall be terminated at each end with an industry-standard LC-type fiber optic connector
- Performance requirements
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- TIA 492-AAAD
- IEC 60793-2-10, A1a.3
- ISO/IEC 11801, OM4
- Shall provide attenuation of less than 3.0 dB per kilometer at an 850 nm wavelength
- Shall provide attenuation of less than 1.2 dB per kilometer at a 1300 nm wavelength
- Shall provide an insertion loss of less than 0.5 dB per 300 meters at 850 nm or 1300 nm
- Shall provide minimum effective mode bandwidth of 4700 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 3500 MHz-km at an 850 nm wavelength
- Shall provide minimum overfill launch bandwidth of 550 MHz-km at a 1300 nm wavelength
- Shall be bend-insensitive fiber for a tight bend radius of 0.3 inches (7.5 mm) with minimal cable losses
- Shall meet or exceed OM4 laser-optimized multimode fiber performance standards
- General requirements
- Shall be available in a thirty (30) meter (98.4 foot) length
- Shall provide an outer dimeter of 0.08" ±0.008" (2.0 mm ±0.2 mm)
- Shall meet regulatory compliance
- ETL/c-ETL OFNP FT6 (plenum rated)
- Shall provide a lifetime limited performance warranty
- Approved cable shall be Extron 2LC OM4 MM P/30 (part number 26-671-30), no alternates or equals